黄曲霉毒素电化学生物传感器
Electrochemical Biosensors for Aflatoxin Analysis
黄曲霉毒素(aflatoxin,AF)是一种具有强烈毒性和强致癌性的生物毒素,对其进行快速而准确的分析是减小和避免黄曲霉毒素危害的最有效手段之一。电化学生物传感器因其快速、灵敏、特异性强、易于微型化等优势在黄曲霉毒素分析受到国内外研究者的广泛关注。目前,应用于黄曲霉毒素分析的电化学生物传感器主要有免疫传感器、酶传感器和DNA传感器。本文综述了不同传感器的研究现状,特别介绍了新材料新技术在黄曲霉毒素免疫分析中发挥的重要作用,并对黄曲霉毒素的电化学生物传感分析存在的问题和发展前景进行了探讨及展望。
Aflatoxin is a kind of biotoxins with acute toxicity and strong carcinogenicity. Quick and accurate analysis is one of the most effective methods to minimize or avoid its hazard. Electrochemical biosensor has drawn widespread attention of domestic and foreign researchers for aflatoxin analysis,due to its rapidity,high degree of sensitivity and specificity, combined with its easiness to be miniaturized. So far, immunosensor, enzyme sensor, and DNA biosensor have been applied to electrochemical biosensing of aflatoxin. In this paper, the research progress of different kinds of sensors for aflatoxin analysis is reviewed. The importance of new materials and advanced technologies for immunoassay of aflatoxin is particularly highlighted. Main problems and trends in electrochemical biosensing of aflatoxin are discussed and prospected.
Contents
1 Introduction
2 Electrochemical immunosensor
2.1 Nanomaterials
2.2 Ionic liquids
2.3 Conducting polymers
2.4 Others
3 Electrochemical enzyme sensor
4 Electrochemical DNA sensor
5 Conclusion and outlook
黄曲霉毒素
aflatoxin
[1] Bakirdere S, Bora S, Bakirdere E G, Aydin F, Arslan Y, Komesli O T, Aydin I, Yildirim E. Cent. Eur. J. Chem., 2012, 10: 675.
[2] Henry S H, Bosch F X, Troxell T C, Bolger P M. Science, 1999, 286: 2453.
[3] Williams J H, Phillips T D, Jolly P E, Stiles J K, Jolly C M, Aggarwal D. Am. J. Clin. Nutr., 2004, 80: 1106.
[4] Gnonlonfin G, Hell K, Adjovi Y, Fandohan P, Koudande D O, Mensah G A, Sanni A, Brimer L. Crit. Rev. Food Sci., 2013, 53: 349.
[5] 蒿艳蓉(Hao Y R), 苏建家(Su J J). 现代预防医学(Modern Preventive Medicine), 2009, 36(1): 146.
[6] 孙桂菊(Sun G J), 钱耕荪(Qian G S), 金锡鹏(Jin X P), 陈建国(Chen J G), 贺霞(He X), 王少康(Wang S K), 蒋兆坤(Jiang Z K), 王加生(Wang J S). 东南大学学报(医学版)(Journal of Southeast University (Medical Science Edition), 2002, 21(1): 118.
[7] 闫培生(Yan P S), 曹立新(Cao L X), 王凯(Wang K), 王琢(Wang Z). 中国农业科技导报(Journal of Agricultural Science and Technology), 2008, 10(6): 89.
[8] 马良(Ma L), 李培武(Li P W), 张文(Zhang W). 分析测试学报(Journal of Instrumental Analysis), 2007, 26(6): 774.
[9] 江湖(Jiang H), 熊勇华(Xiong Y H), 许杨(Xu Y). 卫生研究(Journal of Hygiene Research), 2005, 34(2): 252.
[10] Arredondo M, Stoytcheva M, Zlatev R, Gochev V. Mini-Rev. Med. Chem., 2012, 12: 1301.
[11] Wu N N, Cao L X, Yan P S, Wang M H. Advanced Materials Research, 2011, 322: 385.
[12] 计结胜(Ji J S). 哈尔滨工业大学硕士论文(Master Dissertation of Harbin Institute of Technology ), 2010.
[13] Buenger D, Topuz F, Groll J. Prog. Polym. Sci., 2012, 37: 1678.
[14] Ammida N H S, Micheli L, Palleschi G. Anal. Chim. Acta, 2004, 520: 159.
[15] Badea M, Micheli L, Messia M C, Candigliota T, Marconi E, Mottram T, Velasco-Garcia M, Moscone D, Palleschi G. Anal. Chim. Acta, 2004, 520: 141.
[16] Ammida N, Micheli L, Piermarini S, Moscone D, Palleschi G. Anal. Lett., 2006, 39: 1559.
[17] Larou E, Yiakoumettis I, Kaltsas G, Petropoulos A, Skandamis P, Kintzios S. Food Control, 2013, 29: 208.
[18] Rameil S, Schubert P, Grundmann P, Dietrich R, Märtlbauer E. Anal. Chim. Acta, 2010, 661: 122.
[19] Liu Y, Qin Z, Wu X, Jiang H. Biochem. Eng. J., 2006, 32: 211.
[20] Li Z J, Wang Z Y, Sun X L, Fang Y J, Chen P P. Talanta, 2010, 80: 1632.
[21] Vig A, Munoz-Berbel X, Radoi A, Cortina-Puig M, Marty J L. Talanta, 2009, 80: 942.
[22] 孙秀兰(Sun X L), 汪忠云(Wang Z Y), 方银军(Fang Y J), 陈佩佩(Chen P P), 李在均(Li Z J). 分析化学(Chinese Journal of Analytical Chemistry), 2010, 38(2): 245.
[23] Tan Y, Chu X, Shen G, Yu R. Anal. Biochem., 2009, 387: 82.
[24] Vig A, Radoi A, Muoz-Berbel X, Gyemant G, Marty J. Sensor. Actuat. B-Chem., 2009, 138: 214.
[25] Pemberton R M, Pittson R, Biddle N, Drago G A, Hart J P. Anal. Lett., 2006, 39: 1573.
[26] Masoomi L, Sadeghi O, Banitaba M H, Shahrjerdi A, Davarani S S H. Sensor. Actuat. B-Chem., 2013, 177: 1122.
[27] Kalita P, Singh J, Singh M K, Solanki P R, Sumana G, Malhotra B D. Appl. Phys. Lett., 2012, 100: 0937029.
[28] Owino J, Arotiba O A, Hendricks N, Songa E A, Jahed N, Waryo T T, Ngece R F, Baker P, Iwuoha E I. Sensors, 2008, 8: 8262.
[29] Owino J, Ignaszak A, Al-Ahmed A, Baker P, Alemu H, Ngila J C, Iwuoha E I. Anal. Bioanal. Chem., 2007, 388: 1069.
[30] Lin D J, Wu J, Wang M, Yan F, Ju H X. Anal. Chem., 2012, 84: 3662.
[31] Zhou J, Lai W Q, Zhuang J Y, Tang J, Tang D P. ACS Appl. Mater. Inter., 2013, 5: 2773.
[32] Gao W C, Dong H F, Lei J P, Ji H X, Ju H X. Chem. Commun., 2011, 47: 5220.
[33] Lai G S, Wu J, Ju H X, Yan F. Adv. Funct. Mater., 2011, 21: 2938.
[34] Yuan L, Xu L L, Liu S Q. Anal. Chem., 2012, 84: 10737.
[35] Liu Q T, Boyd B J. Analyst, 2013, 138: 391.
[36] Wang X D, Chen L J, Su X R, Ai S Y. Biosens. Bioelectron., 2013, 47: 171.
[37] Zhou L T, Li R Y, Li Z J, Xia Q F, Fang Y J, Liu J K. Sensor. Actuat. B-Chem., 2012, 174: 359.
[38] Sharma A, Matharu Z, Sumana G, Solanki P R, Kim C G, Malhotra B D. Thin Solid Films, 2010, 519: 1213.
[39] Singh C, Srivastava S, Ali M A, Gupta T K, Sumana G, Srivastava A, Mathur R B, Malhotra B D. Sensor. Actuat. B-Chem., 2013, 185: 258.
[40] Srivastava S, Kumar V, Ali M A, Solanki P R, Srivastava A, Sumana G, Saxena P S, Joshi A G, Malhotra B D. Nanoscale, 2013, 5: 3043.
[41] Li J P, Li S H, Yang C F. Electroanal., 2012, 24: 2213.
[42] Chikkaveeraiah B V, Bhirde A A, Morgan N Y, Eden H S, Chen X Y. ACS Nano, 2012, 6: 6546.
[43] Piermarini S, Volpe G, Micheli L, Moscone D, Palleschi G. Food Control, 2009, 20: 371.
[44] Paniel N, Radoi A, Marty J L. Sensors, 2010, 10: 9439.
[45] Tang D P, Zhong Z Y, Niessner R, Knopp D. Analyst, 2009, 134: 1554.
[46] Soleymani L, Fang Z C, Sargent E H, Kelley S O. Nat. Nanotechnol., 2009, 4: 844.
[47] de la Escosura-Muniz A, Merkoci A. ACS Nano, 2012, 6: 7556.
[48] Ongaro M, Ugo P. Anal. Bioanal. Chem., 2013, 405: 3715.
[49] Varshney M, Li Y B. Biosens. Bioelectron., 2009, 24: 2951.
[50] Fan Z Y, Ho J C, Takahashi T, Yerushalmi R, Takei K, Ford A C, Chueh Y L, Javey A. Adv. Mater., 2009, 21: 3730.
[51] 曹立新(Cao L X), 闫培生(Yan P S), 孙克宁(Sun K N), KirK D W. 化学进展(Progress in Chemistry), 2008, 20(9): 1276.
[52] Cao L X, Yan P S, Sun K, Kirk D W. Electroanal., 2009, 21: 1183.
[53] Cao L X, Yan P S, Sun K N, Wirk D W. Electrochim. Acta, 2008, 53: 8144.
[54] Cao L, Yan P, Sun K, Kirk W D. Chinese J. Chem., 2007, 25: 1754.
[55] Ghosh H, Roychaudhuri C. 2012 Sixth International Conference on Sensing Technology (ICST 2012). Kolkata: IEEE, 2012. 688.
[56] Ghosh H, Roychaudhuri C. Appl. Phys. Lett., 2013, 102: 243701.
[57] Parker C O, Lanyon Y H, Manning M, Arrigan D, Tothill I E. Anal. Chem., 2009, 81: 5291.
[58] Shiddiky M, Torriero A. Biosens. Bioelectron., 2011, 26: 1775.
[59] Hasanzadeh M, Shadjou N, Eskandani M, de la Guardia M. Trac-Trend. Anal. Chem., 2012, 41: 58.
[60] 闫燕(Lv Y), 杨启炜(Yang Q W), 邢华斌(Xing H B), 苏宝根(Su B G), 任其龙(Ren Q L). 化学进展(Progress in Chemistry), 2012, 24(5): 659.
[61] Sun A L, Qi Q A, Dong Z L, Liang K Z. Sens. & Instrumen. Food Qual., 2008, 2: 43.
[62] Cosnier S, Holzinger M. Chem. Soc. Rev., 2011, 40: 2146.
[63] Ates M. Mat. Sci. Eng. C-Mater., 2013, 33: 1853.
[64] Dinçkaya E, K?n?k Ö, Sezgintürk M K, Altu D? Ç, Akkoca A. Artif. Cell., Blood Sub. Biotech., 2012, 40: 385.
[65] Bacher G, Pal S, Kanungo L, Bhand S. Sensor. Actuat. B-Chem., 2012, 168: 223.
[66] Bacher G, Kanungo L, Bhand S. 2012 Sixth International Conference on Sensing Technology (ICST 2012). Kolkata: IEEE, 2012. 29.
[67] Pohanka M, Malir F, Roubal T, Kuca K. Anal. Lett., 2008, 41: 2344.
[68] Piermarini S, Volpe G, Ricci F, Micheli L, Moscone D, Palleschi G, Fuhrer M, Krska R, Baumgartner S. Anal. Lett., 2007, 40: 1333.
[69] Piermarini S, Micheli L, Ammida N H S, Palleschi G, Moscone D. Biosens. Bioelectron., 2007, 22: 1434.
[70] Micheli L, Grecco R, Badea M, Moscone D, Palleschi G. Biosens. Bioelectron., 2005, 21: 588.
[71] Neagu D, Perrino S, Micheli L, Palleschi G, Moscone D. Int. Dairy J., 2009, 19: 753.
[72] Parker C O, Tothill I E. Biosens. Bioelectron., 2009, 24: 2452.
[73] Lillehoj P B, Huang M, Truong N, Ho C. Lab Chip, 2013, 13: 2950.
[74] Tang C K, Vaze A, Rusling J F. Lab Chip, 2012, 12: 281.
[75] Kobayashi N, Oyama H. Analyst, 2011, 136: 642.
[76] Techera A G, Kim H J, Gee S J, Last J A, Hammock B D, Sapienza G G. Anal. Chem., 2007, 79: 9191.
[77] Clark L C J, Lyons C. Ann. N. Y. Acad. Sci., 1962, 102: 29.
[78] 刘大岭(Liu D L), 沈奕(Shen Y), 张静(Zhang J), 姚冬生(Yao D S). 中国生物工程杂志(China Biotechnology), 2008, 28(3): 44.
[79] Li S C, Chen J H, Cao H, Yao D S, Liu D L. Food Control, 2011, 22: 43.
[80] Ben Rejeb I, Arduini F, Arvinte A, Amine A, Gargouri M, Micheli L, Bala C, Moscone D, Palleschi G. Biosens. Bioelectron., 2009, 24: 1962.
[81] Hansmann T, Sanson B, Stojan J, Weik M, Marty J, Fournier D. Biosens. Bioelectron., 2009, 24: 2119.
[82] Zhou M, Dong S J. Accounts Chem. Res., 2011, 44: 1232.
[83] Du Y, Li B L, Wang E K. Accounts Chem. Res., 2013, 46: 203.
[84] Siontorou C G, Nikolelis D P, Miernik A, Krull U J. Electrochim. Acta, 1998, 43: 3611.
[85] Mascini M, Palchetti I, Marrazza G. Fresen. J. Anal. Chem., 2001, 369: 15.
[86] Wang J S, Groopman J D. Mutat. Res. -Fund. Mol. M., 1999, 424: 167.
[87] Eaton D L, Gallagher E P. Annu. Rev. Pharmacol., 1994, 34: 135.
[88] Banitaba M H, Davarani S, Mehdinia A. Anal. Biochem., 2011, 411: 218.
[89] Dinçkaya E, K?n?k Ö, Sezgintürk M K, Altu Ç, Akkoca A. Biosens. Bioelectron., 2011, 26: 3806.
[90] Nguyen B H, Tran L D, Do Q P, Nguyen H L, Tran N H, Nguyen P X. Mat. Sci. Eng. C-Mater., 2013, 33: 2229.
/
| 〈 |
|
〉 |