蛋白质磷酸化作用的电化学检测方法
Electrochemical Detection of Protein Phosphorylation
蛋白质的磷酸化作用是一种可逆的翻译后修饰方式,几乎参与生物体内所有关键生命活动,在核内基因的特定表达、细胞的分裂分化以及各种生命活动的转导中发挥重要意义。基于磷酸化前后电化学信号的改变,利用电化学传感器的方法能快速简便地检测蛋白质的磷酸化作用,且具有较高的选择性和灵敏度。本文回顾了几种常用的电化学检测磷酸化作用的方法,基于电极材料的不同进行了分类与总结,汇总了每种方法中用到的修饰电极的纳米材料及生物分子,最后总结了电化学方法检测蛋白质磷酸化的优缺点,并对有效检测磷酸化作用进行了前景展望。
The phosphorylation of proteins is a reversible post-translational modification, which is almost involved in all the life activities in organisms. Protein phosphorylation plays a significant role in specific genes expressing, cell proliferation and differentiation, especially in the further transduction of various life activities. Based on the changes of electrochemical signal, protein phosphorylation can be detected conveniently by electrochemical methods because of its high sensitivity and selectivity. This review summarizes several electrochemical methods for the detection of phosphorylation based on the electrode materials, and the common materials or molecules using for electrode modification. At the end of this review, the advantages and disadvantages, as well as a prospect of effective electrochemical detection of phosphorylation are given.
Contents
1 Introduction
2 The electrochemical detection for protein phosphorylation based on modified electrode
3 Several methods about electrode modification
3.1 Monolayer modified electrode
3.2 Multi molecular layer modified electrode
4 Several common modified electrodes used for electrochemical detection of protein phosphorylation
4.1 Electrochemical biosensor based on screen printed electrodes
4.2 Substrate peptide modified gold electrode
4.3 Glassy carbon electrodes
4.4 Indium tin oxide electrodes
4.5 Other modified electrodes
5 Conclusion and outlook
phosphorylation
[1] 王京兰(Wang J L), 钱小红(Qian X H). 分析化学(Chinese Journal of Analytical Chemistry), 2005, 33(7): 1029.
[2] 姜铮(Jiang Z), 王芳(Wang F), 荷湘(He X), 刘大伟(Liu D W), 陈宣男(Chen X N), 赵庆红(Zhao Q H), 黄留玉(Huang L Y), 袁静(Yan J). 生物技术通讯(Letters in Biotechnology), 2009, 20(2): 233.
[3] Hunter T. Philos. Trans. R. Lond Soc. B Biol. Sci., 1998, 353(1368): 583.
[4] Reimand J, Waqih O, Bader G D. Sci. Rep., 2013, 3(2651): 1.
[5] Saqili K D, Raju R, Reddy V R, Anandaraj M P, Suneetha S, Suneetha L M. J. Infect. Dev. Ctries., 2008, 2(2): 124.
[6] Freeman R, Finder T, Gill R, Willner I. Nano Lett., 2010, 10(6): 2192.
[7] Nelson C A, Szczech J R, Dooley C J, Xu Q, Lawrence M J, Zhu H, Jin S, Ge Y. Anal. Chem., 2010, 82(17): 7193.
[8] Kim Y P, Oh E, Oh Y H, Moon D W, Lee T G, Kim H S. Angew. Chem. Int. Ed., 2007, 46(36): 6816.
[9] Shapiro M G, Szablowski J O, Langer R, Jasanoff A. J. Am. Chem. Soc., 2009, 131(7): 2484.
[10] Xu X H, Nie Z, Chen J H, Fu Y C, Li W, Shen Q P, Yao S Z. Chem. Commun(Camb)., 2009, 45: 6946.
[11] Zhou N D, Cao Y, Li G X. Sci. China Chem., 2010, 53(4): 720.
[12] Li G X, Miao P. Electrochemical Analysis of Proteins and Cells. Spring, 2013. 19.
[13] Song H, Kerman K, Kraatz H B. Chem. Commun(Camb)., 2008, 4: 502.
[14] Du D, Wang L M, Shao Y Y, Wang J, Engelhard M H, Lin Y. Anal. Chem., 2011, 83(3): 746.
[15] 赵鹏(Zhao P), 徐霞红(Xu X H), 周立分(Zhou L F), 刘欣(Liu X), 聂舟(Nie Z), 姚守拙(Yao S Z). 化学传感器(Chemical Sensors), 2011, 31(1): 3.
[16] 赵倩(Zhao Q), 朱小立(Zhu X L), 李根喜(Li G X). 电化学(Journal of Electrochemistry), 2012, 18(2): 97.
[17] Lane R F, Hubbard A T. J. Phys. Chem., 1973, 77(11): 1401.
[18] Watkins B F, Behling J R, Kariv E, Miller L L. J. Am. Chem. Soc., 1975, 97(12): 3549.
[19] Moses P R, Wier L, Murray R W. Anal. Chem., 1975, 47(12): 1882.
[20] 李佳(Li J), 徐金瑞(Xu J R), 孙向英(Sun X Y). 分析化学(Chinese Journal of Analytical Chemistry), 2002, 30(2): 206.
[21] 姜荣中(Jiang R Z), 许莉娟(Xu L J), 金日镇(Jin R Z), 董绍俊(Dong S J). 分析化学(Chinese Journal of Analytical Chemistry), 1985, 13(4): 270.
[22] Huang J F. Talanta, 2009, 77(5): 1694.
[23] Guaus E, Errachid A, Torrent-Burgués J. J. Electroanal. Chem., 2008, 614(1/2): 73.
[24] Xie S B, Yuan R, Chai Y Q, Bai L J, Yuan Y L, Wang Y. Talanta, 2012, 98: 7.
[25] Li C Y. Colloids Surf. B, 2007, 50(2): 147.
[26] 周艳丽(Zhou Y L), 只金芳(Zhi J F). 第10届全国有机电化学与工业学术会议论文集(Proceedings of the 10th National Meeting of Organic Electrochemistry and Industry), 2007.
[27] Xie Q J, Zhang Y Y, Xu M C, Li Z L, Yuan Y, Yao S Z. J. Electroanal. Chem., 1999, 478(1/2): 1.
[28] Jin B, Wang G X, Millo D, Hildebrandt P, Xia X H. J. Phys. Chem. C, 2012, 116(24): 13038.
[29] Wang G X, Bao W J, Wang M, Xia X H. Chem. Commun(Camb)., 2012, 48(88): 10859.
[30] Jin B, Bao W J, Wu Z Q, Xia X H. Langmuir, 2012, 28(25): 9460.
[31] Liu X Q, Wang X H, Zhang J M, Feng H Q, Liu X H, Wong D K. Biosens. Bioelectron., 2012, 35(1): 56.
[32] Yin F, Shin H K, Kwon Y S. Biosens. Bioelectron., 2005, 21(1): 21.
[33] Vasudev A, Kaushik A, Bhansali S. Biosens. Bioelectron., 2013, 39(1): 300.
[34] Chitravathi S, Kumara-Swamy B E, Mamatha G P, Chandrashekar B N. J. Mol. Liq., 2012, 172: 130.
[35] Xie Y Y, Chen A Q, Du D, Lin Y H. Anal. Chim. Acta, 2011, 699(1): 44.
[36] Kerman K, Vestergaard M, Chikae M, Yamamura S, Tamiya E. Electrochem. Commun., 2007, 9(5): 976.
[37] Kerman K, Chikae M, Yamamura S, Tamiya E. Anal. Chim. Acta, 2007, 588(1): 26.
[38] Albareda-Sirvent M, Merkoci A, Alegret S. Sens. Actuators B, 2001, 79: 48.
[39] 左少华(Zuo S H), 张玲帆(Zhang L F), 滕渊洁(Teng Y J), 袁慧慧(Yuan H H), 蓝闽波(Lan M B). 现代仪器(Modern Instruments), 2008, 2: 13.
[40] Snir E, Joore J, Timmerman P, Yitzchaik S. Langmuir, 2011, 27(17): 11212.
[41] Miao P, Ning L M, Li X X, Li P F, Li G X. Bioconjugate chem., 2012, 23(1): 141.
[42] Wang J, Cao Y, Li Y, Liang Z Q, Li G X. J. Electroanal. Chem., 2011, 656(1/2): 274.
[43] Wang J, Shen M, Cao Y, Li G X. Biosens. Bioelectron., 2010, 26(2): 638.
[44] Rains M K, Marti Dc S, Freeman D, Kraatz H B. ACS Chem. Neurosci., 2013, 4(8): 1194.
[45] Martic S, Rains M K, Kraatz H B. Anal. Biochem., 2013, 442(2): 130.
[46] 杨茜璐(Yang Q L), 朱微(Zhu W), 张冬梅(Zhang D M), 周楠迪(Zhou N D). 分析实验室(Chinese Journal of Analysis Laboratory), 2011, 30(3): 1.
[47] Wang M, Wang G X, Xiao F N, Zhao Y, Wang K, Xia X H. Chem. Commun(Camb)., 2013, 49(78): 8788.
[48] Che X, Yuan R, Chai Y Q, Li J J, Song Z J, Wang J F. J. Colloid Interface Sci., 2010, 345(2): 174.
[49] Popa O M, Diculescu V C. J. Electroanal. Chem., 2013, 689: 216.
[50] Cao Q, Zhao H, Yang Y M, He Y J, Ding N, Wang J, Wu Z J, Xiang K X, Wang G W. Biosens. Bioelectron., 2011, 26(8): 3469.
[51] Tang L A, Wang J, Lim T K, Bi X, Lee W C, Lin Q, Chang Y T, Lim C T, Loh K P. Anal. Chem., 2012, 84(15): 6693.
[52] Leitner A, Sturm M, Lindner W. Anal. Chim. Acta, 2011, 703(1): 19.
[53] Wu J H, Li X S, Zhao Y, Zhang W P, Guo L, Feng Y Q. J. Chromatogr. A, 2011, 1218(20): 2944.
[54] Sturm M, Leitner A, Smått J H, Lindén M, Lindner W. Adv. Funct. Mater., 2008, 18(16): 2381.
[55] He X X, Chen Z F, Wang Y H, Wang K M, Su J, Yan G P. Biosens. Bioelectron., 2012, 35(1): 134.
[56] Eriksson A, Bergquist J, Edwards K, Hagfeldt A, Malmström D, Hernández V A. Anal. Chem., 2011, 83(3): 761.
[57] Zarei M, Sprenger A, Metzger F, Gretzmeier C, Dengjel J. J. Proteome Res., 2011, 10(8): 3474.
[58] Armistead P M, Thorp H H. Anal. Chem., 2000, 72(16): 3764.
[59] Yang Y, Guo L H, Qu N, Wei M Y, Zhao L X, Wan B. Biosens. Bioelectron., 2011, 28(1): 284.
[60] Kerman K, Kraatz H B. Biosens. Bioelectron., 2009, 24(5): 1484.
[61] 杨郁(Yang Y), 郭良宏(Guo L H), 曲娜(Qu N), 韦明元(Wei M Y). 第十一届全国电分析化学会议论文集(Proceedings of the 11th National Conference on Analytical Chemistry), 2011.
[62] Qu N, Wan B, Guo L H. Analyst, 2008, 133(9): 1246.
[63] Chiku M, Horisawa K, Doi N, Yanagawa H, Einaga Y. Biosens. Bioelectron., 2010, 26(1): 235.
[64] 高成耀(Gao C Y), 常明(Chang M), 李晓伟(Li X W), 李翠平(Li C P).化学进展(Progress in Chemistry), 2011, 23(5): 951.
[65] Du D, Wang J, Lu D, Dohnalkova A, Lin Y. Anal. Chem., 2011, 83(17): 6580.
[66] Ji J, Yang H, Liu Y, Chen H, Kong J L, Liu B H. Chem. Commun(Camb)., 2009, 12: 1508.
/
| 〈 |
|
〉 |